Khetsi International
Request a quote

Khetsi International Assured

Six systems.
One risk each.

Each Assured system is built around the one mistake a clinician cannot afford. The product facts are on this page. The documents come with your quotation.

Operating theatre

When the count says correct, the X-ray still has to agree.

X-ray detectable abdominal pads and gauze swabs.

  • X-ray detectable thread, woven in
  • 100% cotton gauze to EN 14079
  • Stitched on all four sides
  • EO sterilized
  • Pads from 25 × 25 to 45 × 45 cm. Swabs from 5 × 5 to 10 × 10 cm, 8 to 16 ply
KI-W016 · KI-W020

Orthopaedics

Tape and padding, specified as one cast.

Fiberglass casting tape with water-repellent cast padding.

  • X-ray transparent: check healing with the cast on
  • Air-permeable tape and padding
  • Padding repels water and dries quickly
  • Tape 7.5 to 15 cm × 3.6 m. Padding 7.5 to 20 cm × 3 m
KI-W014 · KI-W015

Oncology

The dose costs more than the set. Protect the dose.

Paclitaxel and photosensitive infusion sets.

  • 0.2 µm in-line filter on the Paclitaxel set
  • DEHP-free fluid pathway
  • Needle-free Y-site, Luer lock, 60 drops/ml, 150 cm
  • Three-layer light-proof tubing on the photosensitive set
KI-M011 · KI-M012

Neonatal intensive care

Built for patients who weigh a kilo.

Measured volume, micro-drip and feeding, specified together.

  • Measured volume set with a 110 or 150 ml chamber
  • Micro infusion set at about 60 drops/ml
  • Infant feeding tube, 5 to 10 FG, with an X-ray opaque line
  • Paediatric urine bag, 100 ml, graduated
  • Scalp vein set down to 27G
KI-M014 · KI-M015 · KI-M017 · KI-M063 · KI-M064

Intensive care

Every infection on the ward report has a name next to it.

Silicone Foley, urometer and drainage bag, as one closed system.

  • Foley catheter in 100% silicone, 6 to 24 Fr
  • Urometer with a 250 or 500 ml chamber
  • Needle-free sampling port
  • Non-return valve
KI-M031 · KI-M032 · KI-M033

Anaesthesia

The machine is shared. The filter shouldn’t be.

BVF-HME breathing filters, one per patient.

  • Bacterial and viral filtration with heat and moisture exchange
  • Adult and paediatric sizes
  • Tidal volume from 150 to 1500 ml
  • Optional gas monitoring port
  • Sterile, single use
KI-M028

The document pack.

The person who signs off a product asks for papers before a sample. Each Assured system has a list.

  • Manufacturer certificates, with holder and scope
  • Specification sheet for each item
  • Sterilisation records, for sterile items
  • Certificate of analysis for each lot

Start with one system.

Tell us the department and the country. We send the document pack, then a sample.